advertisement

Topcon

Abstract #56446 Published in IGR 16-1

Standard Trabeculectomy and Ex-PRESS Miniature Glaucoma Shunt: A Comparative Study and Literature Review

Moisseiev E; Zunz E; Tzur R; Kurtz S; Shemesh G
Journal of Glaucoma 2015; 24: 410-416


PURPOSE: The aim of this study was to compare the efficacy and safety between standard trabeculectomy and the Ex-PRESS shunt implantation. METHODS: A retrospective review of the records of 100 eyes of 100 patients who underwent trabeculectomy or Ex-PRESS shunt implantation between July 2010 and June 2012 was conducted. Of these, 61 (61%) eyes underwent trabeculectomy and 39 (39%) eyes underwent Ex-PRESS shunt implantation. Demographic information, glaucoma type, surgical details, preoperative, and postoperative data including intraocular pressure (IOP), number of medications, reoperation, and occurrence of any complications were recorded. RESULTS: No differences in IOP reduction or number of postoperative IOP-lowering medications were demonstrated between the 2 procedures. Success rates were 86.9% for trabeculectomy and 84.6% for Ex-PRESS shunt. Rates of failure and hypotony were not significantly different between the groups. No parameter was correlated with success or failure of any procedure. CONCLUSIONS: Standard trabeculectomy and Ex-PRESS shunt have similar efficacy and safety profiles. As the Ex-PRESS shunt is considerably more expensive, its use may be unjustified, especially as a primary procedure.This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivitives 3.0 License, where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially. http://creativecommons.org/licenses/by-nc-nd/3.0.

Full article

Classification:

12.8.2 With tube implant or other drainage devices (Part of: 12 Surgical treatment > 12.8 Filtering surgery)



Issue 16-1

Change Issue


advertisement

Oculus