advertisement
Basic Science: Trabecular Pigmentation is not correlated to Outflow (24-2, July 2024) on:
112998 Lack of Correlation Between Segmental Trabecular Meshwork Pigmentation and Angiographically Determined Outflow in Ex-Vivo Human Eyes
Strohmaier CA; Wanderer D; Zhang X et al.
Journal of Glaucoma 2023; 0:
Basic Science: Modelling the biomechanics of the ONH and cornea (23-4, October 2023) on:
107711 The Effects of Negative Periocular Pressure on Biomechanics of the Optic Nerve Head and Cornea: A Computational Modeling Study
Safa BN; Bleeker A; Bleeker A; Bleeker A; Berdahl JP et al.
Translational vision science & technology 2023; 12: 5
Clinical Examination Methods: 24-hour monitoring to detect Glaucoma Progression (23-4, October 2023) on:
107957 24-Hour Monitoring of Intraocular Pressure Fluctuations Using a Contact Lens Sensor: Diagnostic Performance for Glaucoma Progression
Gaboriau T; Dubois R; Foucque B et al.
Investigative Ophthalmology and Visual Science 2023; 64: 3
Telemedicine: . . . And through an implantable sensor (23-3, July 2023) on:
105972 EYEMATE-SC Trial: Twelve-Month Safety, Performance, and Accuracy of a Suprachoroidal Sensor for Telemetric Measurement of Intraocular Pressure
Szurman P; Gillmann K; Seuthe AM et al.
Ophthalmology 2023; 130: 304-312
Clinical Forms of Glaucoma: Glaucoma after Vitreoretinal Surgery (23-1, October 2022) on:
100408 Risk of glaucoma after vitreoretinal surgery - Findings from a population-based cohort study
Loukovaara S; Gucciardo E; Korhonen A et al.
Acta Ophthalmologica 2022; 100: 665-672
Telemedicine: Implanted Sensors Can Telemonitor IOP Over 10 Years (22-4, July 2022) on:
99170 Telemetric non-contact intraocular pressure monitoring with an implanted sensor in patients with glaucoma: long-term safety report and monitoring data
Schmidt I; Plange N; Walter P et al.
British Journal of Ophthalmology 2023; 107: 1098-1103
Clinical Examination Methods: IOP and PERG (21-3, March 2021) on:
90632 Use of a novel telemetric sensor to study interactions of intraocular pressure and ganglion-cell function in glaucoma
Al-Nosairy KO; Al-Nosairy KO; van den Bosch JJON; Pennisi V et al.
British Journal of Ophthalmology 2021; 105: 661-668
Miscellaneous: IOP-Lowering through Vacuum Application (21-1, November 2020) on:
84916 The effects of negative periocular pressure on intraocular pressure
Ethier CR; Yoo P; Berdahl JP
Experimental Eye Research 2020; 191: 107928
Risk Factors in Glaucoma: IOP Variation and Glaucoma (19-2, September 2018) on:
75758 Variation in Intraocular Pressure and the Risk of Developing Open-Angle Glaucoma: The Los Angeles Latino Eye Study
Jiang X; Torres M; Varma R et al.
American Journal of Ophthalmology 2018; 188: 51-59
Animal Models: Pulsatile aqueous outflow in primates (18-3, July 2017) on:
71574 Aqueous Angiography in Living Nonhuman Primates Shows Segmental, Pulsatile, and Dynamic Angiographic Aqueous Humor Outflow
Huang AS; Li M; Yang D et al.
Ophthalmology 2017; 124: 793-803
Basic Science: An implantable device for telemetric IOP monitoring (18-1, February 2017) on:
69389 Investigation of a novel implantable suprachoroidal pressure transducer for telemetric intraocular pressure monitoring
Mariacher S; Ebner M; Januschowski K et al.
Experimental Eye Research 2016; 151: 54-60
Clinical Examination Methods: Real-Time Aqueous Outflow Imaging (17-3, June 2016) on:
66251 Aqueous Angiography: Real-Time and Physiologic Aqueous Humor Outflow Imaging
Saraswathy S; Tan JC; Yu F et al.
PLoS ONE 2016; 11: e0147176
Surgical Treatment: SLT in NPG (15-4, September 2014) on:
55392 Comparison of Fluctuations of Intraocular Pressure Before and After Selective Laser Trabeculoplasty in Normal-tension Glaucoma Patients
Tojo N; Oka M; Miyakoshi A et al.
Journal of Glaucoma 2014; 23: e138-e143
Pathophysiology: Factors affecting IOP (14-4, July 2013) on:
51987 Effect of Lateral Decubitus Position on Intraocular Pressure in Glaucoma Patients with Asymmetric Visual Field Loss
Kim KN; Jeoung JW; Park KH et al.
Ophthalmology 2013; 120: 731-735
Comments (13-3, December 2011) on:
46409 Aqueous humor dynamics during the day and night in volunteers with ocular hypertension
Fan S; Hejkal JJ; Gulati V et al.
Archives of Ophthalmology 2011; 129: 1162-1166
Basic Research - RGC: Cyclical shear stress (13-3, December 2011) on:
46708 Are intracranial pressure fluctuations important in glaucoma?
Wostyn P; De Groot V; Audenaert K et al.
Medical Hypotheses 2011;
IOP and Trabecular Meshwork: Asymmetry of IOP fluctuations (13-2, October 2011) on:
45511 Asymmetry of diurnal intraocular pressure fluctuation between right and left eyes
Kim MS; Kim JM; Park KH et al.
Acta Ophthalmologica 2011; 89: 352-357
Intraocular Pressure: Aqueous humor dynamics change from day to night (13-1, June 2011) on:
27790 Aqueous Humor Dynamics During the Day and Night in Healthy Mature Volunteers
Liu H; Fan S; Gulati V et al.
Archives of Ophthalmology 2011; 129: 269-275
Surgical Therapy: Increased outflow facility after SLT (12-4, March 2011) on:
27539 Effect of primary selective laser trabeculoplasty on tonographic outflow facility: a randomised clinical trial
Goyal S; Beltran-Agullo L; Rashid S et al.
The British journal of ophthalmology 2010; 94: 1443-1447
Intraocular Pressure and Outflow: In-vivo measurement diameter Schlemm's canal (12-2, September 2010) on:
26148 Variation in Schlemm's canal diameter and location by ultrasound biomicroscopy
Irshad FA; Mayfield MS; Zurakowski D et al.
Ophthalmology 2010; 117: 916-920
Basic Research: CSF and glaucoma (12-1, June 2010) on:
25137 Cerebrospinal Fluid Pressure in Glaucoma A Prospective Study
Ren R; Jonas JB; Tian G et al.
Ophthalmology 2010; 117: 259-266
Intraocular Pressure: Waterdrinking test and longterm IOP variation (11-2, September 2009) on:
23699 Agreement between stress intraocular pressure and long-term intraocular pressure measurements in primary open angle glaucoma
De Moraes CG; Furlanetto RL; Reis AS et al.
Clinical and Experimental Ophthalmology 2009; 37: 270-274
Intraocular pressure: GAT calibration (9-4, March 2008) on:
19914 Calibration errors of Goldmann tonometers in a tertiary eye care centre
Chuo JY; Mikelberg FS
Canadian Journal of Ophthalmology 2007; 42: 712-714
Examination methods: Aqueous humor (8-4, March 2007) on:
15137 Concordance of aqueous humor flow in the morning and at night in normal humans
Radenbaugh PA; Goyal A; McLaren NC et al.
Investigative Ophthalmology and Visual Science 2006; 47: 4860-4864
Clinical glaucoma: NPG - IOP (8-4, March 2007) on:
15103 Diurnal variation of intraocular pressure in suspected normal-tension glaucoma
Hasegawa K; Ishida K; Sawada A et al.
Japanese Journal of Ophthalmology 2006; 50: 449-454
Death (8-3, December 2006) on:
14109 Open-angle glaucoma and cardiovascular mortality: the Blue Mountains Eye Study
Lee AJ; Wang JJ; Kifley A et al.
Ophthalmology 2006; 113: 1069-1076